Before EtherNet/IP brought the Common Industrial Protocol onto standard Ethernet in 1999, ODVA already had a network built specifically for deterministic, scheduled control traffic: ControlNet, running over RG-6 coaxial cable or optical fiber at speeds up to 5 Mbps, with support for trunkline-dropline, star, and tree topologies and fully redundant cabling as a built-in option. ControlNet's entire design premise was that control traffic and configuration traffic should never compete for bandwidth unpredictably, so it split the network's time into repeating intervals and gave every scheduled connection a guaranteed slot within each one — a level of built-in determinism that standard Ethernet, before ControlNet's Ethernet-based successor existed at all, simply could not offer. Every ControlNet node still implements the same underlying CIP object model and shares CIP device profiles with EtherNet/IP and DeviceNet devices, which is why Embien's guide to the Common Industrial Protocol treats ControlNet as one physical-layer option among several rather than a separate protocol family.
ControlNet's determinism comes from its Concurrent Time Domain Multiple Access scheme, which repeats a fixed Network Update Time interval on every node's local clock and reserves scheduled slots within that interval for time-critical connections, with unscheduled traffic filling whatever bandwidth is left over. EtherNet/IP takes a different route to real-time behavior: it separates explicit, TCP-based configuration messaging from implicit, UDP-based I/O messaging, and where truly hard determinism is required, layers CIPSync time synchronization, compliant with IEEE 1588, on top of standard switched Ethernet rather than reserving network-wide time slots the way ControlNet does natively. Both approaches solve the same underlying problem, guaranteeing that control data arrives when it is supposed to, but ControlNet guarantees it structurally at the network-access layer while EtherNet/IP achieves comparable guarantees through switch quality, network design discipline, and, where needed, TSN-aware infrastructure.
New ODVA-ecosystem projects overwhelmingly specify EtherNet/IP rather than ControlNet, and the reasons are mostly about everything surrounding the protocol rather than the protocol's core determinism. EtherNet/IP runs on commodity Ethernet switches, cabling, and network interface hardware that IT departments already stock, support, and understand, where ControlNet requires dedicated coax or fiber infrastructure, specialized taps, and network-planning tools most plant networking teams no longer maintain expertise in. EtherNet/IP also inherits the entire modern Ethernet ecosystem's pace of improvement, higher link speeds, better diagnostics, easier integration with IT-side IP infrastructure, none of which ControlNet, as a fixed-purpose fieldbus frozen at 5 Mbps, can meaningfully keep pace with. The underlying CIP device profiles a device implements barely change between the two networks; what changes is almost entirely the physical and access layer beneath them.
It would be inaccurate to call the move from ControlNet to EtherNet/IP a strict upgrade with nothing given up. ControlNet's scheduled time-slot guarantee is structural — a properly configured ControlNet segment simply cannot have a scheduled connection miss its slot because of unrelated network congestion, since the network-access protocol itself prevents that contention from occurring. A switched EtherNet/IP network achieves comparable reliability through careful VLAN segmentation, QoS configuration, and adequate switch capacity, but that reliability is a property of how well the network was engineered and maintained, not a guarantee built into the wire access method itself, which is a meaningful distinction for the small set of applications with genuinely hard, safety-relevant timing requirements and minimal tolerance for network misconfiguration.
A plant with a meaningful ControlNet installed base rarely benefits from a forklift replacement, since ControlNet hardware that has run reliably for fifteen or twenty years is not, on its own, a failure waiting to happen. The more common and lower-risk path is a phased migration: new cells and new machines get specified on EtherNet/IP from the outset, existing ControlNet segments are bridged to the EtherNet/IP backbone through a CIP-aware linking device rather than replaced outright, and full ControlNet retirement happens opportunistically as individual ControlNet nodes reach end of life or as a broader line rebuild creates a natural cutover point. Choosing between ControlNet and EtherNet/IP for ODVA networks in a brownfield plant is less a single decision than an ongoing one, revisited machine by machine as capital projects come up rather than forced all at once.
A direct ControlNet vs EtherNet/IP ODVA network comparison comes down to a small number of practical differences: physical media, coax or fiber against standard copper or fiber Ethernet; determinism model, native scheduled time slots against engineered switch-level QoS; maximum throughput, 5 Mbps against 100 Mbps to multi-gigabit; and ecosystem, a shrinking pool of ControlNet-specific tools and expertise against the entire modern Ethernet toolchain. Every device on either network still implements the same CIP device profiles, the same object model, and largely the same application-layer behavior, which is precisely why a linking device can bridge the two networks without translating application semantics at all — only the access-layer and physical-layer framing actually differ.
It is worth stating plainly what stays identical across this whole comparison: ODVA CIP device profiles< — the predefined object sets that give a photoelectric sensor, an AC/DC drive, or an encoder the same configurable attributes regardless of which physical network it sits on — are a CIP-layer concept, not a ControlNet or EtherNet/IP-specific one. A drive built against a standard ODVA CIP device profile behaves the same way, exposes the same attributes, and is configured the same way whether it is deployed on a ControlNet segment or an EtherNet/IP cell, which is exactly why migrating the physical network underneath a device does not require reworking the device profile, the configuration tool, or the EDS file that describes it.
A plant weighing ControlNet against EtherNet/IP is very often the same plant that should be weighing network redundancy strategy at the same time, since ControlNet's native support for fully redundant cabling is one of its most-cited remaining advantages over a naively wired EtherNet/IP segment. As covered in Embien's piece on EtherNet/IP Device Level Ring network redundancy, DLR closes most of that gap on the EtherNet/IP side, giving a modern EtherNet/IP cell sub-millisecond ring failover that is directly comparable to what ControlNet's redundant-cable option has offered for decades. A migration plan that pairs an EtherNet/IP move with a properly designed DLR ring, rather than a flat, single-path Ethernet topology, addresses the redundancy objection that otherwise keeps some ControlNet segments in service longer than their throughput and tooling limitations alone would justify.
Embien Technologies develops CIP-compliant embedded firmware and network integration across the full ODVA physical-layer family, EtherNet/IP, ControlNet, and DeviceNet, and supports plants planning a phased migration from legacy ControlNet segments toward EtherNet/IP backbones without disrupting production. Our device-profile and object-model implementation work draws directly on the CIP foundation described in Embien's guide to the Common Industrial Protocol, applied consistently across whichever physical network a customer's installed base actually runs.
To plan a ControlNet-to-EtherNet/IP migration or a new ODVA network built around modern CIP device profiles, reach out to Embien's engineering team.

Embien delivers embedded engineering solutions across industrial automation and IoT, supporting connected devices, industrial controllers, communication gateways, and equipment integration through hardware, firmware, and system engineering.

Embien's embedded software development services cover firmware development, device drivers, CIP object model implementation, and industrial protocol-stack integration across EtherNet/IP, ControlNet, and DeviceNet for connected industrial devices and network migration projects.

A case study demonstrating Embien's industrial communication engineering through the development of a protocol converter for wind turbine systems, highlighting protocol translation and integration between industrial equipment and monitoring networks, relevant to brownfield network connectivity and migration.